Operating and installation instructionsCooker hoodsDA 216-2, DA 216-2 EXTDA 217-2DA 219-2, DA 219-2 EXTIt is essential to read theseoperating instruct
Functional descriptionThe cooker hood works with. . . air extractionThe air is drawn in and cleaned by thegrease filters and directed outside.The cook
OperationMain switchSwitch the main switch to "I". The fanand the lighting can now be operated. If the appliance is not going to be usedfor
To switch the fan offPress the On/Off touch control toswitch the fan off.The indicator lamp above the controlgoes out.Switching the lighting onThe hob
Filter operating hours counterThe number of hours the appliance hasbeen in operation for is stored in mem-ory.The indicator lamp above the grease fil-
Altering the filter operating hourscounterThe operating hours counter for thegrease filters is set to 30 hours. Thiscan be lengthened or shortened to
Setting/altering the active charcoalfilter operating hours counterThe active charcoal filters are onlyused for cooker hoods which are setup for recirc
Cleaning and careBefore any cleaning or maintenancework the cooker hood must be dis-connected from the mains supply.Ensure that:– it is switched off a
Grease filtersRe-usable metal filters are fitted whichremove solid particles (oil, dust, etc.)from the kitchen vapours, preventingsoiling of the cooke
Fitting / replacing the activecharcoal filtersIf the cooker hood is connected for re-circulation, two active charcoal filtersmust be inserted in addit
Changing a light tubeDisconnect the cooker hood fromthe mains supply. Ensure that:– it is switched off at the wall socketand the plug has been withdra
ContentsCaring for the environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Warning and Safety instructio
Appliance dimensionsAppliance dimensions20
Safety regulations prohibit the fittingof this cooker hood over a solid fuelstove.For safety reasons a minimum safedistance must be maintained be-twee
InstallationAssembly partsInstallation22
b 2 recirculation grilles(for recirculation mode only) c 2 protective sheets for use when fitting the tower.d 1 protective sheet for use when fitti
Retaining platesThere are three retaining plates A, Band C for fixing the cooker hood to thewall. First of all drill the holes for attachingthe canopy
Lightly secure retaining plate A intoposition using 5 x 40 mm screwsthrough the two holes and use thenotches to align with the middle line.Drill 4 mor
At a maximum distance of 365 mmfrom the ceiling, hold retaining plateC against the wall and use the not-ches to align it with the middle line.Mark the
Motor unit(not when operating the external fan)with air extractionIf a non-return flap is not present inthe venting system, the non-returnflap supplie
Control unit(only when operating with an externalfan)Fit the exhaust socket supplied into thecanopy. It has an integrated non-returnflap. If a 150 mm
For appliances connected to an ex-ternal fan, model designation...EXT: Connect the control unit and the ex-ternal fan with the connection cableand the
Caring for the environmentDisposal of packing materialThe transport and protective packinghas been selected from materialswhich are environmentally fr
RecirculationIf site conditions are not suitable for thecooker hood to be used for air extrac-tion the appliance must be connectedfor recirculation.Pu
Before fitting the extension pieceremove the protective foil.Bend the top hanging retainers ap-prox. 45° inwards. This makes fittingeasier.Recirculati
The paper protective sheet protects theextension piece from being scratchedwhen the tower is being fitted. It isremoved when fitting is complete.Fold
Hold the main tower gently apart andfit it over the extension piece.Then slide the tower down approx.2 cm into the canopy.Adjust the tower.Remove the
Connection for air extractionDanger of toxic fumes.Please heed the "Warning andSafety instructions" to avoid thedanger of toxic fumes.The co
Important:If the exhaust ducting is to run throughrooms, ceiling space etc. where theremay be great variations in temperaturebetween the different are
Electrical connection All electrical work should be under-taken by a suitably qualified andcompetent person in strict accord-ance with national and lo
Important The wires in the mains lead are col-oured in accordance with the followingcode:Green/yellow = earthBlue = neutralBrown = liveIf the applianc
After Sales ServiceIn the event of a fault which you cannotcorrect yourself please contact:– Your Miele Dealeror– The Miele Service Department (see ba
Technical data Rated loadDA 216-2, 217-2, 219-2 . . . . . . . 222 WLighting . . . . . . . . . . . . . . . . . 2 x 11 WVoltageUK, IRL, NZ . . . . . .
Warning and Safety instructionsThis appliance conforms to currentsafety requirements. Incorrect usecan lead to injury and damage tothe appliance.Befor
Alteration rights reserved / 44 / 000 GB / IRL / AUS / NZ / ZA – 1301This paper consists of cellulose which has been bleached without the use of chlor
The appliance is only completelyisolated from the electricity supplywhen:– it is switched off at the wall socketand the plug removed. (Do not pullon t
InstallationThe distance between the top ofthe cooker/hob and the bottom ofthe cooker hood must measure at least:– 450 mm above electric hobs andcooke
When using the cooker hood inextraction mode at the same timeas another heating appliance which de-pends on the air in the room, (e.g. gas,oil or coal
Description of the applianceDescription of the appliance8
b Extension piecec Towerd Canopye Control panelf Main switchg Recirculation grillesh Hob lighting iGrease filtersjTouch control for the hob lighting