To check the first intake of air
a Adjusting screw
b Air intake sleeve
Gap X must measure:
For natural gas: 6 mm
For liquid gas: 13 mm
To set gap X
^ Loosen screw a and adjust air intake
sleeve b. Then retighten screw a.
To change the small jets
a Small diameter jet
(e.g. for liquid gas: 0.23)
b Large diameter jet
(e.g. for liquid gas: 0.60)
^ Using a small screwdriver, unscrew
the two small jets a and b in the gas
fitting.
^ Pull out the jets with a pair of pliers.
^
Fit the correct jets securely (see jet
table).
^
Finally, secure the jets against
inadvertent loosening with sealing
wax.
Conversion to another type of gas