To check the first intake of air
a Retaining screw
b Air intake sleeve
Gap X must measure:
For natural gas: 13 mm
For liquid gas: 13 mm
If it doesn't:
^
Loosen the retaining screw, adjust
the air intake sleeve, and tighten the
retaining screw again.
^
Finally secure the jets against
inadvertent loosening with sealing
wax.
^
Re-assemble the cooktop in the
reverse order.
The flame must not go out on the lowest
setting, or when the control is turned
quickly from a high to a low setting.
On the highest setting the flame must
have a distinctive and visible core.