Miele H 370 Technical Information Seite 58

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 102
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 57
Novotronic Models
Technical Information
58
6.2.3 Fault Code F5
Cause
Oven PTC temperature short-circuited
Remedy
Replace the PTC sensor
6.2.4 Fault Code F6
Cause
Safety cutouts tripped
Remedy
Turn the selector switch to O” to reset the cutout.
6.2.5 Fault Code F9
Cause
The electronic temperature is too high (Temp > 175 degrees F) because
of insufficient cooling air or lack of proper ventilation
Remedy
Check the cooling air and vapor paths.
Ensure the cabinet that houses the oven allows for proper ventilation
(refer to operating instructions)
Cause
The electronic temperature is too high (Temp > 175 degrees F) because
the cooling fan is defective.
Remedy
Replace the cooling fan