6.3 Fault Repair
6.3.1 Excessive Noise During Convection Fan Operation
Cause
Convection heating element defective
Note
To check the convection element, insert a screwdriver opening to used to
hold the grease filter and press lightly on the element while the
convection fan is running. If the noise stops replace the convection
element
Parts required
Quantity Material Number Nomenclature
1 04986670 Fan oven element (ring)
Remedy
Replace the convection heating element
Cause
The fan axel has too much play
Remedy
Replace the convection heating fan