To convert the burners
,
Turn off the main gas supply (if
the appliance has already been
installed) and disconnect the
appliance from the main electrical
power supply before proceeding.
To change the jets and needle valves
the appliance has to be opened by
removing the burners.
Removing the burners
^
Remove the grates, the burner cap,
a, the burner base, b.
^
Loosen the screws, c, and take off
the cooktop surface.
The following jets and needle valves
should be installed into their respective
burners. Follow codes accordingly.
Conversion table KM 360
Code Jet size
(Ø mm)
Code Needle
valve size
(Ø mm)
Natural gas
Auxilliary
burner
92 0.92 42 0.42
Normal
burner
115 1.15 52 0.52
Fast
burner
165 1.65 60 0.60
Propane (LP)
Auxilliary
burne
56 0.56 23 0.23
Normal
burner
72 0.72 29 0.29
Fast
burner
92 0.92 40 0.40