Miele KM 453 Betriebsanleitung Seite 35

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 52
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 34
Safety clearance underneath the
cooktop
To ensure sufficient ventilation to the
cooktop, a certain gap must be left
between the underside of the cooktop
and any oven, interim shelf or drawer.
The minimum gap between the
underside of the cooktop and
the top of an oven is 15 mm.
the top of an interim shelf is 15 mm.
the base of a drawer must be
75 mm.
Interim shelf
It is not necessary to install an interim
shelf underneath the cooktop.
A gap of 10 mm is needed at the back
for laying the mains connection cable.
For better cooktop ventilation, however,
a gap of 20 mm is recommended.
Safety clearances
35
Seitenansicht 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 51 52

Kommentare zu diesen Handbüchern

Keine Kommentare