Make the worktop cut-out following
the dimensions shown above.
^
Remember to maintain a minimum
safety distance of 50 mm between
the hob and the back wall and a side
wall to the right or left of the hob. See
"Warning and Safety instructions".
^
Seal the cut surfaces with a suitable
sealant to avoid swelling caused by
moisture.
The materials used must be heat re
-
sistant.
Protective base
^
A protective base must be installed
underneath the hob. There must be a
gap of at least 15 mm between the
hob and the base (see illustration).
If during installation the corners of
the frame are not flush with the
worktop surface, the corner radius,
Max R4 can be carefully scribed to
suit.
Appliance dimensions and worktop cut-out
13
15
10
min.
50