(CDN) (USA) Instructions for building-in
Prepare the cooktop cut-out as illus-
trated.
Dimension "B" applies for a combina-
tion of appliances and is given on
the chart.
Dimension "X":
CDN:
The typical depth of a counter-
top is 635 mm. "X" must be a mini-
mum of 90 mm.
USA: "X" must be a minimum of 2 1/4".
2 zone Combiset
1 Combiset
2 Combisets
3 Combisets
4 Combisets
5 Combisets
4 zone Combiset
1 Combiset
2 Combisets
3 Combisets
Combination
One 2 zone
+ one 4 zone
Two 2 zone
+ one 4 zone
Three 2 zone
+ one 4 zone
One 2 zone
+ two 4 zone
Two 2 zone
+ two 4 zone
Depth
in
mm
490
490
490
490
490
490
490
490
490
490
490
490
490
Width *
(= Dimen-
sion B)
in mm
265
558
851
1144
1437
560
1143
1728
851
1143
1437
1436
1729
Extractor (e.g. DA 8-2)
For building in between two appliances:
- Dimension B increases by 90 mm.
For building in at the end of a combination:
- Dimension B increases by 98 mm.
* Width includes provision lor V 98 spacer bar.
2G
(CDN) (USA) Instructions for building-in
2 zone Combiset
1 Combiset
2 Combisets
3 Combisets
4 Combisets
5 Combisets
19-5/16"
19-5/16"
19-5/16"
19-5/16"
19-5/16-
Depth
in
inch
Width *
(= Dimen-
sion B)
in inch
10-7/16"
22"
33-1/2"
45-1/32"
56-9/16-
4 zone Combiset
1 Combiset
2 Combisets
3 Combisets
Combination
One 2 zone
+ one 4 zone
Two 2 zone
+ one 4 zone
Three 2 zone
+ one 4 zone
One 2 zone
+ two 4 zone
Two 2 zone
+ two 4 zone
19-5/16"
19-5/16"
19-5/16"
19-5/16"
19-5/16"
19-5/16"
19-5/16"
19-5/16"
22'
45"
68"
33-1/2"
45"
56-9/16"
56-1/2"
68-1/16"
Extractor (e.g. DA 8-2)
For building in between two appliances:
- Dimension B increases by 3 9/16".
For building in at the end of a combination:
- Dimension B increases by 3 7/8".
* Width includes provision for V 98 spacer bar.
Place the seal provided © under the
edge of the cooktop.
© Appliance
® Tensioning screw
© Clamp
© Countertop
©Seal
• Turn the tensioning screws © in a -
clockwise direction © until a resist-
ance is felt, then turn the clamp to
the left.
• Place the appliance in position, turn
the clamps and tighten the tension-
ing screws until the clamps just
touch the countertop ©. Do not over-
tighten.
• Connect the appliance to the electri-
cal supply.
When building-in several Combiset
units,
a stainless steel spacer bar (V 98
edge connector) must be installed be-
tween each unit. It is supplied with its
own installation instructions.
Kommentare zu diesen Handbüchern